Alcance
                            This document specifies a test method for determining the leaktightness of elastomeric sealing ring type joints for buried thermoplastics non-pressure piping systems.Unless otherwise specified in the referring standard, the tests are carried out at the following basic test pressures:—     p1: internal negative air pressure (partial vacuum);—     p2: a low internal hydrostatic pressure;—     p3: a higher internal hydrostatic pressure.It also describes the following four test conditions under which the tests are performed:a)   Condition A: without any additional diametric or angular deflection;b)   Condition B: with diametric deflection;c)   Condition C: with angular deflection;d)   Condition D: with simultaneous angular and diametric deflection.The applicable selection of the test pressure(s) and the test condition(s) is/are specified in the referring standard.