ISO/IEC TR 11801-9911:2024
Information technology — Generic cabling for customer premises — Part 9911: Guidelines for the use of balanced single pair applications within a balanced 4-pair cabling system
Autor:
ISO
-
-
-
-
Vigente
$143.990
Alcance
This document, which is a Technical Report,a) describes the rules of implementation of balanced single pair as described by ISO/IEC 11801-6:2017/AMD1:202x within a balanced 4- pair cabling system with a current carrying capacity of 0,75 A per conductor;b) describes the use of components and cabling to implement and configure according to ISO/IEC 11801-6:2017/AMD1:202xc) describes links and components for generic single pair channels according to ISO/IEC 11801-1:2017/AMD1:202x. Particular areas of interest are:• remote powering according to IEEE Std 802.3, Clause 104• loop resistance, max. current • insertion loss• return loss • noise considerations • frequency range requirements (low and high)• length calculation of the SCP-Link-4-pair-cable• number of channelsd) describes the use of application specific single pair channels in addition to ISO/IEC 11801:2017/AMD1:202x, 6.6.4e) describes guidance on single pair remote powering applications when using 4-pair cabling with current carrying capacity specifiedf) describes guidelines for planning, administration and installation